冷媒回收機 Refrigerants Recovery
Refrigerant Recovery Systems – for all applications and all refrigerants including R-410A.
All are backed by the experience of having more units in the field than the total of many different competitive units combined.
Building block approach to select a system for your needs
Make your selection based on system size, your budget, and performance features that build through the line. On this page, start with the high speed of the R 60a. Add automatic operation with the R 70a and then subcooling with the R 80a System.
Every unit is full-function tested in the factory to help insure trouble-free operation. Results and a full 1-year warranty are included with each unit. Optional 2-year warranty on the compressor is also available for the R 60a, R 70a, and R 80a.
Call 1-800-769-8370 for technical support for as long as you own the equipment. Telephone calls typically solve 90% of problems without returns. Technical support is also available in Europe. Replacement parts are easy to install and readily available through your YELLOW JACKETR wholesaler.
Since Federal laws prohibit venting or blowing off a charge during service calls, a recovery unit is mandatory.

R 60a SERIES REFRIGERANT RECOVERY SYSTEMS –
fast recovery of most refrigerants including R-410A

Yellow Jacket System R 60a is rated as fast or faster than all competitive units in the ARI directory or UL listings for most CFC, HCFC, and HFC refrigerants including R-410A. Features include all of the following:
‧ Fast recovery with pumping straight liquid refrigerant at up to 4 lbs./min., and vapor at 2 lbs./min.
‧ Durability with proven 1/2 hp oil-less direct drive compressor. Permanently lubricated cylinder walls eliminate oil maintenance and compatibility problems.
‧ Built-in 200 mesh particulate filter to protect unit from dirty systems.
‧“On-the-fly” purge with simple turn of a knob to remove residual refrigerant and help prevent cross contamination.
‧ Easy, intuitive use with 2-valve set-up and no hose switching.
‧ Quiet running with components nested to reduce vibration and noise. Oil-less compressor is inherently quiet. Tough polypropylene case dampens vibration rather than amplify it like metal.
‧ High volume air flow ducted over oversized condenser for cool running even in high ambient temperatures.
‧ Controls and gauges inset for protection and angled for easy access and viewing.
‧ High strength construction for rugged use, yet lightweight at less than 30 pounds. (13.6 kg). Rounded corners help protect you and your customers property from scrapes.
High efficiency fan keeps air moving across an oversized condenser for cool running even in high temperature operating conditions.
The weight of all units balance away from the side of your leg for easier carrying on a long walk to the back of a house or a long climb to a roof top.
Engineered for Safety
All YELLOW JACKETR Recovery Systems are UL tested and certified to ARI 740-95 or ARI 740-98 standards. UL also tests some R 60a, R 70a, and R 80a units for safety during CUL and CE testing.
Safety features include the following:
‧ Single high pressure switch helps prevent confusion and guard against tank blow off even in high ambient temperatures.
‧ Oversized condenser with high velocity fan blade increases cooling to help keep the pressure down especially in higher ambient temperatures.
‧ CPR valve on the R 70a and R 80a are rated at 600 psi for trouble free operation.
Note: All YELLOW JACKETR Recovery Systems are UL recognized and we recommend you use UL recognized hoses for safety.

UPC

Product Description

TOS*
Compressor
Electrical

94960

R 60a Refrigerant Recovery System

-
1/2 HP
oil less
115 V
60 HZ

94962

R 62a recovery machine

Std.
1/2 HP
oil less
115 V
60 HZ

94963

R 63a Refrigerant Recovery System
- CE - Euro 2 pin plug

-
1/2 HP
oil less
230 V
50 HZ

94965

R 65a Refrigerant Recovery System - CE

-
1/2 HP
oil less
110 V
50 HZ
94967
R 63a Refrigerant Recovery System
– CE– UK 3 pin plug
-
1/3 HP
oil less
230 V
50 HZ
R-70a SERIES UNIVERSAL RECOVERY SYSTEMS
–adds fully automatic operation to the speed of R-60a
Start with the features of the R 60a at left and add fully automatic operation for every refrigerant. R 70a is the first truly automatic recovery system for most refrigerants. There’s not even a switch to touch for R-410A. Now you’ve got the freedom to work elsewhere after hook-up. You can run at record speed with totally automatic changeover from liquid to vapor. Pump liquid refrigerant at up to 4 lbs./min.; vapor at up to 2 lbs./min.
Advanced 1/2 hp, 3425 rpm oil-less compressor with precision valves manufactured in an ISO-9001 facility.
Pulls 15" vacuum then shuts off and on automatically to maintain vacuum.
LED signals recovery completion.
High efficiency fan keeps air moving across an oversized fan for cool running even in hot weather.
Senses back pressure from tank and shuts off automatically at 520 psi for safety.
Single high pressure safety switch.
Reusable 200 mesh filter insets into suction port for protection. Simple cleaning eliminates replacement due to clogging.
Color-coded hook-ups for proper use.
“On-the-fly” purge with simple turn of a knob to remove residual refrigerant and help prevent cross contamination.
Designed and manufactured in USA and approved by a major Japanese A/C manufacturer as the only unit to pass their stringent testing.
Tested by UL to ARI 740-98.
Engineered for Safety
All YELLOW JACKETR Recovery Systems are UL tested and certified to ARI 740-95 or ARI 740-98 standards. UL also tests some R 60a, R 70a, and R 80a units for safety during CUL and CE testing.
Safety features include the following:
Single high pressure switch helps prevent confusion and guard against tank blow off even in high ambient temperatures.
Oversized condenser with high velocity fan blade increases cooling to help keep the pressure down especially in higher ambient temperatures.
CPR valve on the R 70a and R 80a are rated at 600 psi for trouble free operation.
Note: All YELLOW JACKETR Recovery Systems are UL recognized and we recommend you use UL recognized hoses for safety.

UPC

Product Description

TOS*
Compressor
Electrical

9497

R 70a Universal Recovery Syste

-
1/2 HP
oil less
115 V
60 HZ

94972

R 72a Universal Recovery System (TOS)

Std.
1/2 HP
oil less
115 V
60 HZ

94973

R 73a Universal Recovery System
- CE - Euro 2 pin plug

-
1/2 HP
oil less
230 V
50 HZ

9497

R 73a Universal Recovery System
– CE– UK 3 pin plug

-
1/3 HP
oil less
230 V
50 HZ

NEW R 80a SERIES UNIVERSAL RECOVERY SYSTEMS
– adds subcooling to the R 70a

When ambient temperatures go up at a service site, refrigerant in the recovery tank gets hot and expands to increase pressure, reducing recovery speed. You could either ice the tank to cool and condense the contents or just flip the subcooling switch on the new R 80a System. The switch is faster and more convenient.

Subcooling lowers the temperature of refrigerant below its dew point. In subcooling mode the R 80a draws hot vapor from the recovery tank and it goes back through the condenser. The vapor is cooled and returned to the tank as a liquid to lower tank temp and pressure. With a cooler tank and lower pressure, you can fill the tank more quickly with more refrigerant on hot days, and help maximize compressor life.

Set-up is a simple 3-hose hook-up when connecting the R 80a to the system and tank. Same as the R 70a at left, recovery is automatic. Subcooling takes only the flip of a switch without changing hoses.

UPC

Product Description

TOS*
Compressor
Electrical

9498

R 80a Universal Subcooling Syste

-
1/2 HP
oil less
115 V
60 HZ
94982
R 82a Universal Subcooling System
Std.
1/2 HP
oil less
115 V
60 HZ
R 100 SERIES REFRIGERANT RECOVERY SYSTEMS
– the speed you need for larger commercial jobs
This is the high speed system for large quantity refrigerant transfer, junkyard transfer, supermarket rack systems, and other larger commercial jobs.

Fast twin cylinder 1 hp oil-less compressor recovers direct liquid at up to 8 lbs/min., or 2 lbs./min. vapor per ARI
740-95.

High capacity 6" muffin fan and oversized 3/8" slit fin condenser with 3-pass path for cool running in high ambient temperatures.
Overfill tank shut-off sensor.
Built-in cleanable 200 mesh particulate filter to protect from dirty systems.
"On-the-fly" purge with simple turn of a knob to remove residual refrigerant and help prevent cross contamination.
Designed and manufactured in USA.
*TOS is tank over fill sensor and switch

UPC

Product Description

TOS*
Compressor
Electrical

95100

R 100 Refrigerant Recovery System (TOS)

Std.
1 HP
oil less
dual cylinders
115 V
60 HZ

YELLOW JACKETR R 50a SERIES REFRIGERANT RECOVERY SYSTEMS –
cost-effective for a wide variety of small to medium systems

The new YELLOW JACKETR R 50a Recovery System combines the best features from the industry-proven original R 50 with many features of the the new R 60a design.

Durability with a proven 1/3 hp oil-less compressor with no brushes to wear and no piston cup seal failures.

Improved air flow and cool running even in high ambient temperatures. High efficiency fan keeps air moving across an oversized condenser.
High strength polypropylene case for lightweight and rugged use. Rounded corners help protect you and your customers from nicks and scrapes.
Built-in cleanable 200 mesh particulate filter to protect from dirty systems.
"On-the-fly" purge with simple turn of a knob to remove residual refrigerant and help prevent cross contamination.
Controls and gauges inset for protection and angled for easy access and
viewing.
Single high pressure safety switch.
Designed and manufactured in USA.

UPC

Product Description

Compressor
Electrical

9493

R 30a Refrigerant Recovery System

1/6 HP
hermetic
115 V
60 HZ

RECOVERY SYSTEMS COMPARISON CHART
RECOVERY SYSTEMS AT A GLANCE

Domestic
R 30a #94930
R 50a #94950
R 60a #94960
R 70a #94970
R 80a #94980
R 100 #95100
Recovery capabilities

Vapor and push/pull

Vapor, liquid, push/pull
Vapor, liquid, push/pull
Vapor, liquid, push/pull
Vapor, liquid, push/pull
Vapor, liquid, push/pull